FAQ on dehumidifiers and humidity control

Questions customers often ask ENCO by hotline and Zalo. Can't find yours? Call 1900 633 514 or message the ENCO Zalo OA.

About ENCO

What is ENCO?

ENCO JSC is a Vietnamese company dedicated to humidity control, operating since 1999. ENCO advises, designs, manufactures, installs and services industrial dehumidifiers, desiccant rotor dehumidifiers, drying systems and dry rooms, and builds the DRYMAX and HARISON brands at the DryMax factory (Cu Chi, Ho Chi Minh City).

About ENCO
Who is ENCO's humidity control expert?

Nguyen Minh Thai, M.Eng. (Justin Nguyen), ENCO's chairman, has worked in humidity control since 1995. He co-authored the book “Humid Air Treatment Engineering” (Science and Technics Publishing House) with Prof. Dr.Sc. Nguyen Duc Hung and serves on the ASHRAE Vietnam Chapter Board of Governors for 2026–2027.

Expert profile
How does ENCO choose a humidity control system for a factory?

In four steps: an initial discussion of your needs, a site survey, a moisture-load calculation, then choosing the right solution and equipment. Survey and quote are free.

Talk to an expert
Where are DRYMAX dehumidifiers made?

At ENCO's DryMax factory in Cu Chi, Ho Chi Minh City, using technology from Canadian partner Naav Solutions Inc. DryMax equipment has been exported to Singapore, Indonesia, Cambodia and other ASEAN countries.

DRYMAX desiccant dehumidifiers
Where can I buy DRYMAX or HARISON industrial dehumidifiers?

Directly from ENCO via hotline 1900 633 514 or info@enco.com.vn. ENCO has head offices in Ho Chi Minh City and Hanoi, a factory in Cu Chi, and service centres in Bac Ninh, Da Nang and Thanh Hoa.

Contact ENCO

Choosing a unit and technical questions

At what humidity does mould grow?

Mould grows quickly from about 70 %RH. Ordinary warehouses should be kept at 50–60 %RH; pharmaceutical stores at 30–45 %RH.

Check your warehouse humidity in 7 days
What is dew point and why does it matter?

Dew point is the temperature at which water vapour in the air starts to condense. Any surface colder than the dew point gets wet: ceilings, floors, ducts, steel surfaces before painting.

How do refrigerant and desiccant dehumidifiers differ?

Refrigerant dehumidifiers (HARISON) cool the air so water condenses; they work well for about 40–60 %RH at normal temperatures. Desiccant rotor dehumidifiers (DRYMAX) use a moisture-absorbing material, reach very low humidity and work well even at low temperatures.

Choose a unit for your needs
What is “nồm” humid weather and what to do?

“Nồm” happens when warm, humid air meets surfaces still cold after a cold spell, so water condenses on walls and floors. Keep doors closed during nồm and use a dehumidifier to lower indoor humidity.

Read about nồm weather
Should I measure humidity before buying a unit?

Measure for 7 days during rain or nồm to know the worst conditions. The data helps ENCO engineers choose the right capacity.

Self-measurement guide

Buying, warranty, service

How do I buy through the website?

Choose a unit, click "Add to quote request" and send your contact details. An ENCO engineer calls you back and sends a signed official quotation. The website does not take online payments.

Purchasing policy
Is the on-site survey free?

Yes. ENCO surveys your site and calculates the moisture load free of charge. A quotation does not commit you to buy.

Book a survey
How do I know what capacity my room needs?

Three things are needed: room volume (m³), the humidity to hold (%RH) and moisture sources (doors, goods, people). Use the Sizing tool for an estimate; an ENCO engineer recalculates during the survey.

Open the Sizing tool
Should I choose HARISON or DRYMAX?

HARISON units are refrigerant dehumidifiers, effective for holding 50–60% RH (warehouses, workshops). DRYMAX uses a desiccant rotor for deep drying below 45% RH and works in cold rooms.

How long is the warranty?

The warranty period depends on the product line and is stated on the warranty card. ENCO covers manufacturing defects.

Warranty policy
Does ENCO have service engineers in my province?

Resident technical teams in Hanoi, Bac Ninh, Quang Ngai and Ho Chi Minh City; service & experience centers in Bac Ninh, Da Nang and Thanh Hoa. Faulty units are handled by the nearest technician.

Does ENCO issue VAT invoices?

Yes. ENCO issues an e-invoice for every order. Payment is by bank transfer to an account in ENCO's name; ENCO never asks you to pay into a personal account.

How soon will I receive the unit?

In-stock units ship quickly to Ho Chi Minh City, Hanoi and other provinces. For made-to-order project equipment, the delivery time is set in the contract.

Delivery & installation
Does ENCO take projects outside Vietnam?

Yes. ENCO has exported equipment to ASEAN countries since 2018. Please send your request to info@enco.com.vn.

What humidity does a cleanroom need?

It depends on the industry and product. Most pharma and electronics cleanrooms hold 30–55 %RH; special zones need lower, down to 20 %RH at 20 °C. The exact figure comes from the product file and the standard the plant follows.

Can cleanroom air conditioning remove moisture on its own?

Partly: the cooling coil condenses water vapour, usually bringing humidity to about 50–60 %RH. Going lower and holding it steady all year needs a desiccant rotor dehumidifier.

What part of a cleanroom project does ENCO handle?

ENCO handles the humidity and temperature control: moisture-load calculation, choosing the solution, supplying, installing and servicing DryMax dehumidifiers, working alongside the project's cleanroom and HVAC contractors.

Paint and blasting shops

View industry solution
Why do paint shops use desiccant rather than refrigerant dehumidifiers?

Desiccant rotors hold a low, stable dew point even when air is cool, and deliver the large airflow that wide blasting areas need.

How many m³/h of dry air does a blasting area need?

It depends on area volume, airtightness, air changes and climate. ENCO engineers survey and calculate the airflow for each site; ENCO projects range from 33,000 to 86,000 m³/h.

What humidity does an aircraft engine store need?

ENCO's project keeps humidity below 45 %RH. The exact level follows the equipment maker's storage requirements.

How do I prove humidity is always within limits?

Use data loggers that record temperature and humidity continuously and export reports; ENCO supplies HOBO and ClimaTech instruments.

Pharmaceuticals and electronics

View industry solution
Can air conditioning bring humidity down to 20 %RH?

No. Ordinary air conditioning brings humidity to about 50–60 %RH; lower levels need a desiccant rotor dehumidifier.

How does DMTH differ from DM?

The DM series only dehumidifies; DMTH has an integrated cooling coil so it handles both temperature and humidity in one unit.

Fresh air for factories

View industry solution
Why treat fresh air separately?

Most of the moisture entering a building comes with fresh air. Dehumidifying it at the source keeps air conditioning from overloading and prevents condensation.

Where is Dry-OA used?

Operating theatres, hospitals, cleanrooms and factories that need dehumidified fresh air.

Storage warehouse

View industry solution
A 300 m² warehouse with a 4 m ceiling needs how many litres per day?

300 m² × 4 m is 1,200 m³. The capacity needed depends on the target humidity, door openings and incoming goods. Enter the figures into the capacity calculator for a first estimate; ENCO engineers check it free of charge.

One large unit or several small ones?

Long warehouses, tall racking or separate zones are better served by several units for even humidity; square, open warehouses can use fewer high-capacity units.

Should I measure humidity before buying a unit?

Measure for 7 days during rain or nồm. ENCO has a self-measurement guide with a printable log sheet.

Agricultural drying

View industry solution
How much energy does the D-He dryer save?

The D-He uses 5.5 kW of electricity for 10.5 kW of useful heat, saving about 10–25% depending on product and process.

Lithium battery dry room

View industry solution
What dew point does a lithium battery dry room need?

Usually −40 °C to −60 °C (below 1 %RH), depending on the process step and line requirements.

What is DryMax-SLD?

ENCO's multi-stage deep dehumidification system, made in Vietnam, used for dry rooms and lithium battery laboratories.